Repair / Repairs / Diagnose a controller fault

Repair

Diagnose a controller fault

Workshop jobCheck safely, then hand it to a workshopTime: 30 to 60 min first assessment (estimate)

The controller (sometimes called the inverter) is the box that takes DC from the battery and feeds the motor in timed pulses. It reads the throttle, brakes, stand switch and Hall sensors, and protects itself and the motor by cutting or reducing power when something is wrong. Many controller "faults" are really a sensor, a switch, a connector or heat. This page is an assessment and hand-off.

Safety

  • The controller holds charged capacitors and connects to the battery and motor phases. Do not open it or unplug its power cables. Isolation is workshop work: Make an electric motorcycle safe to work on.
  • A burning smell from the controller is a serious warning (Letrigo). Switch off and stop riding.
  • Do not fit a "universal" controller from another bike. Wrong settings can overheat the motor or battery and remove safety cut-outs.

Steps

What the rider can check:

  1. Record the code and when it happens: Read electric drive error codes.
  2. Check the interlocks first: Check the throttle, brake and stand interlocks.
  3. Check the controller's air flow: is it covered by mud, a bag, or a new panel? Upway lists sustained load, poor air flow and high air temperature as the main causes of controller heat. See Check cooling of the motor and controller.
  4. Note whether the problem comes after long climbs, heavy loads or hot days and goes away after a rest. That pattern points to heat protection, not a broken controller.
  5. Look (do not touch) for melted connectors, burnt marks or water near the controller.
  6. Hand the bike to the dealer or fleet workshop.

What the workshop will do:

  1. Read the full fault history and live data (throttle signal, temperatures, battery voltage, Hall states) with the manufacturer's tool.
  2. Check the low-voltage supply and fuses to the controller.
  3. Check throttle sensor, brake and stand inputs against the manufacturer's values. There is no universal throttle voltage.
  4. Isolate the HV system and inspect the power connectors and phase connectors: Check motor phase connectors.
  5. Check the main contactor and pre-charge circuit (the circuit that charges the controller's capacitors gently before the contactor closes) using the manual's method.
  6. Separate controller from motor faults: Check motor position (Hall) sensors and Diagnose a motor fault.
  7. Replace the controller only with the correct part, with matching software and settings, and test ride.

What to ask for

  • The code list, live data that proved the fault, and whether software was updated.
  • Whether the controller or the motor was at fault.

Check your work

  • No code, full power, and normal temperature over a test ride with a climb.

If it did not fix the problem

Problems this repair helps with

Sources

Values marked K-Light 125 are for that reference bike. Use your own bike's manual for its values. Text CC BY-SA 4.0, Transitions Lab.